3M™ Cold Shrink QT III 7600 T 3W Series Termination Kit includes a non skirted, 3 phase termination. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric constant material and sealing compounds allows the termination to withstand voltages of 5 to 35kV.
BIL | 95 kV |
Brands | 3M™ |
Breakout Boot | Yes |
Cable Insulation Outside Diameter Range | 0.50-0.70 in, 0.33-0.50 in, 0.92-1.18 in |
Cable Insulation Outside Diameter Range (metric) | 12.7-17.8 mm, 8.4-12.7 mm, 23.4-30.0 mm |
Case Quantity | 1 |
Conductor Sizes (Imperial) | 1 AWG, 2 AWG, 4 AWG, 6 AWG, 8 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 400 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil |
Indoor/Outdoor | Indoor Non-skirted |
Insulation Level | 100%, 133% |
Insulation Outer Diameter (Imperial) | 0.33 in, 0.34 in, 0.35 in, 0.36 in, 0.37 in, 0.38 in, 0.39 in, 0.4 in, 0.41 in, 0.42 in, 0.43 in, 0.44 in, 0.45 in, 0.46 in, 0.47 in, 0.48 in, 0.49 in, 0.5 in, 0.51 in, 0.52 in, 0.53 in, 0.54 in, 0.55 in, 0.56 in, 0.57 in, 0.58 in, 0.59 in, 0.6 in, 0.61 in, 0.62 in, 0.63 in, 0.64 in, 0.65 in, 0.66 in, 0.67 in, 0.68 in, 0.69 in, 0.7 in, 1.06 in |
Insulation Outer Diameter (metric) | 8.382 mm, 8.636 mm, 8.89 mm, 9.144 mm, 9.398 mm, 9.652 mm, 9.906 mm, 10.16 mm, 10.414 mm, 10.668 mm, 10.922 mm, 11.176 mm, 11.43 mm, 11.684 mm, 11.938 mm, 12.192 mm, 12.446 mm, 12.7 mm, 12.954 mm, 13.208 mm, 13.462 mm, 13.716 mm, 13.97 mm, 14.224 mm, 14.478 mm, 14.732 mm, 14.986 mm, 15.24 mm, 15.494 mm, 15.748 mm, 16.002 mm, 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm |
Insulation Rejacketing | Yes |
Lug/Stem Connector Included in Kit | No |
Maximum Installed Length | 8.50 in |
Number of Conductors | 3 |
Product Series | 7600-T-3W |
Shielding Type | Wire Shield, UniShield®, Tape Shield, Wire-Over-Tape Shield |
Voltage | 5 kV, 8 kV, 10 kV, 15 kV |
Safety Data Sheets
Document Number: MSDS_2654606_GB_EN
(PDF)
Safety Data Sheets
Document Number: MSDS_2654440_GB_EN
(PDF)
Thank you for your interest in 3M. In order to help us manage and respond to your query effectively, we politely ask you to provide some key information, including your contact details. The information you provide will be used to respond to your request through email or telephone by a 3M representative or one of our authorised business partners with whom we might share your personal information consistent with the 3M privacy policy
We have received your message and are now looking into your enquiry
One of our representatives will get in touch with you by phone or email