3M™ Wye Resin Splice Kits

  • Options available
  • | Select product options for IDs.

Designed for use on non-shielded cables

Insulates and seals wye splices for compression tap connectors

Fits both split bolt and crimped conductors

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)
icn_down_arrow
icn_down_arrow
icn_down_arrow
icn_down_arrow
icn_down_arrow

Select product options

Details

Highlights
  • Designed for use on non-shielded cables
  • Insulates and seals wye splices for compression tap connectors
  • Fits both split bolt and crimped conductors
  • RoHS 2011/65/EU Compliant

3M™ Scotchcast™ Wye Resin Splice Kits are designed for insulating and sealing wye splices for compression tap connectors on power cables.

Insulates and seals wye splices for compression tap connectors (e.g., C tap or H tap) rated for cables up to 5 kV. Number of Conductors: 1 for 5 kV Multiple for 1 kV

Typical Properties

Cable Diameter Main Cable

8 - 22 mm, 14 - 30 mm, 18 - 26 mm, 23 - 35 mm, 28 - 47 mm, 29 - 34 mm, 33 - 55 mm, 45 - 70 mm, 47 - 80 mm

Cable Type

multi core, polymeric insulated cable, multi core, non shielded, rubber insulated reeling cables

Conductor Amount

Multiple

Flame Retardant

Yes, No

For connection of paper - with plasticinsulated cables

No

Halogen Free

Yes, No

Maximum Conductor Size

6 mm², 10 mm², 25 mm², 50 mm², 95 mm², 120 mm², 150 mm², 240 mm²

Maximum Insulation Outside Diameter

22 mm, 26 mm, 30 mm, 34 mm, 35 mm, 47 mm, 55 mm, 70 mm, 80 mm

Minimum Conductor Size

1.5 mm², 16 mm², 25 mm², 50 mm², 95 mm², 150 mm²

Minimum Insulation Outer Diameter (Metric)

8 mm, 14 mm, 18 mm, 23 mm, 28 mm, 29 mm, 33 mm, 45 mm, 47 mm

Mining Sector Approval

No

Model

Cast Resin

Number of Conductors

4 , 5

Resin Type

SC 470, SC 1402FR, SC 2131

Shelf Life

36 Month

Splice Type

Inline, Jacket Repair & Inline

Voltage

1 kV

Voltage Application

Low Voltage

Voltage Rating

0,6/1 kV

Voltage Row

0.6/1 kV

With Screw Connectors

No

Resources

Safety Data Sheets

Document Number: MSDS_2730265_GB_EN

(PDF)

Safety Data Sheets

Document Number: MSDS_2978591_GB_EN

(PDF)

Connect with us. We’re here to help.

Need help finding the right product for your project? Contact us if you need product, technical or application advice or want to collaborate with a 3M technical specialist

Send Us a Message

Thank you for your interest in 3M. In order to help us manage and respond to your query effectively, we politely ask you to provide some key information, including your contact details. The information you provide will be used to respond to your request through email or telephone by a 3M representative or one of our authorised business partners with whom we might share your personal information consistent with the 3M privacy policy

  • Select One 
  • Select One 
  • United Kingdom
  • Enter your language
  • Select One 
  •  
  •  
  •  
  •  
  •  
  • 3M takes your privacy seriously. 3M and its authorized third parties will use the information you provided in accordance with our Privacy Policy to send you communications which may include promotions, product information and service offers. Please be aware that this information may be stored on a server located in the U.S. If you do not consent to this use of your personal information, please do not use this system.

  • Send Message

Thank you for your contacting 3M

We have received your message and are now looking into your enquiry
One of our representatives will get in touch with you by phone or email

An error occurred.


Similar products

Voltage 1 kV
Maximum Insulation Outside Diameter 22 mm, 26 mm, 30 mm, 34 mm, 35 mm, 47 mm, 55 mm, 70 mm, 80 mm
Minimum Insulation Outer Diameter (Metric) 8 mm, 14 mm, 18 mm, 23 mm, 28 mm, 29 mm, 33 mm, 45 mm, 47 mm
Maximum Conductor Size 6 mm², 10 mm², 25 mm², 50 mm², 95 mm², 120 mm², 150 mm², 240 mm²
Minimum Conductor Size 1.5 mm², 16 mm², 25 mm², 50 mm², 95 mm², 150 mm²
Cable Type multi core, polymeric insulated cable, multi core, non shielded, rubber insulated reeling cables