3M™ Cold Shrink Medium Voltage termination kit QT II series, thanks to the cold shrink silicon insulation body provides an easy and secure solution for MV cable termination.
3M™ Cold Shrink Medium Voltage accessories series QT II are designed using a unique Cold Shrink delivery system. Products are supplied prestretched on a removable core for efficiency and easy of installation. Electrical field control device preinstalled in the insulation body help to avoid complexity during the installation. The specific properties of the insulating silicon body allow to terminate wide range of cable cross sections. 3M™ MV termination kits are available both with and without mechanical lugs included. 3M™ Cold Shrink Medium Voltage accessories are designed to provide an easy and secure solution to terminate MV cables.
Applications | Cable Termination |
Brands | 3M™ |
Breakout Boot | Yes, No |
Cable Insulation Outside Diameter Range (metric) | 33-53 mm, 11,2 - 16,5 mm, 15,9 - 30,0 mm, 16,0 - 28,4 mm, 16,2 - 22,1 mm, 16,2 - 28,4 mm, 19,8 - 33,0 mm, 21,3 - 35,0 mm, 22,6 - 41,4 mm, 27,2 - 49,3 mm, 27,4 - 45,7 mm, 31,5 - 61,5 mm, 33,0 - 53,3 mm, 33,3 - 53,3 mm, 44,0 - 66,0 mm, 14.2 - 22.1 mm |
Cable Type | Polymeric insulated, copper screened, armored/unarmored cable, Polymeric insulated, copper wire screened, unarmored cable |
Indoor/Outdoor | Indoor (12/20 kV) / Outdoor (6/10 kV), Indoor (18/30 kV) / Outdoor (12/20 kV), Indoor, Outdoor, Indoor Skirted |
Insulation Outer Diameter (Imperial) | 0.65 in, 0.87 in, 1.118 in, 1.18 in, 1.3 in, 1.378 in, 1.63 in, 1.8 in, 1.94 in, 2.086 in, 2.098 in, 2.42 in, 2.598 in, 1377 in |
Insulation Outer Diameter (metric) | 16.5 mm, 22.1 mm, 28.4 mm, 30 mm, 33 mm, 35 mm, 41.4 mm, 45.7 mm, 49.3 mm, 53 mm, 53.3 mm, 61.5 mm, 66 mm |
Lug/Stem Connector Included in Kit | No |
Maximum Conductor Size | 25 mm², 50 mm², 70 mm², 95 mm², 150 mm², 240 mm², 300 mm², 400 mm², 500 mm², 630 mm², 1000 mm² |
Maximum Conductor Size (Imperial) | 4 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 300 kcmil, 500 kcmil, 600 kcmil, 750 kcmil, 1000 kcmil, 1243 kcmil, 1974 kcmil |
Minimum Conductor Size | 16 mm², 25 mm², 35 mm², 50 mm², 70 mm², 95 mm², 120 mm², 185 mm², 240 mm², 300 mm², 400 mm², 500 mm² |
Minimum Conductor Size (Imperial) | 2 AWG, 4 AWG, 6 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 250 kcmil, 400 kcmil, 500 kcmil, 600 kcmil, 750 kcmil, 1000 kcmil |
Number of Conductors | 1 , 3 |
Number of Skirts | 0 , 4 , 6 , 8 , 12 |
Product Type | Cold Shrink |
Shielding Type | Wire Shield, Tape Shield, Non-shielded |
Smallest Saleable Unit | Each, Kit |
Voltage | 36 kV, 45 kV, 6/10 kV, 12/20 kV, 18/30 kV |
Voltage Application | Medium Voltage |
Voltage Rating | 6/10 kV, 12/20 kV, 18/30 kV, 26/45 kV |
Voltage Row | 6/10 kV, 12/20 kV, 18/30 kV |
Safety Data Sheets
Document Number: MSDS_3364585_GB_EN
(PDF)
Safety Data Sheets
Document Number: MSDS_1026566_GB_EN
(PDF)
Thank you for your interest in 3M. In order to help us manage and respond to your query effectively, we politely ask you to provide some key information, including your contact details. The information you provide will be used to respond to your request through email or telephone by a 3M representative or one of our authorised business partners with whom we might share your personal information consistent with the 3M privacy policy
We have received your message and are now looking into your enquiry
One of our representatives will get in touch with you by phone or email