3M™ Cold Shrink Medium Voltage termination Kit QT-III series with integrated sealing mastic. Thanks to the cold shrink silicon insulation body QT-III provides an easy and secure solution for medium voltage cable termination, with improved environmental resistant properties.
For polymeric power cable systems, use 3M™ Cold Shrink Termination QT-III. Our termination kits are designed for power cables with copper wire screen according to HD 620 (IEC 60502) and cover a wide application range. They feature a prefabricated one-piece cold shrink termination body, which allows fast and easy installation on a wide range of cable types and sizes, at temperatures ranging from -20 °C to +50 °C. No heat/flame or special tools are required for the installation. 3M™ Cold Shrink Termination QT-III meets and exceeds the requirements of European Standard CENELEC HD 629.1 and IEC 60502-4.
Applications | Cable Termination |
BIL | 95 kV |
Brands | 3M™ |
Breakout Boot | No, Yes |
Cable Insulation Outside Diameter Range | 0.70-0.92 in |
Cable Insulation Outside Diameter Range (metric) | 16,3 - 27,4 mm, 21,1 - 38,8 mm, 21,1 - 38,9 mm, 26,7 - 45,7 mm, 38,6 - 51,0 mm, 38,9 - 58,9 mm, 17.8-23.4 mm |
Cable Outside Diameter (Imperial) | 1.48 in, 1.87 in |
Cable Outside Diameter (metric) | 37.6 mm, 47.5 mm |
Cable Type | Polymeric insulated, copper wire screened, unarmored cable |
Case Quantity | 1 |
Conductor Sizes (Imperial) | 3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil |
Indoor/Outdoor | Outdoor, Indoor, Indoor Non-skirted, Indoor/Outdoor |
Insulation Level | 100%, 133% |
Insulation Outer Diameter (Imperial) | 0.701 in, 1.08 in, 1.53 in, 1.8 in, 2.31 in, 2.32 in |
Insulation Outer Diameter (metric) | 17.8 mm, 27.4 mm, 38.9 mm, 45.7 mm, 58.9 mm |
Insulation Rejacketing | Yes |
Lug/Stem Connector Included in Kit | No |
Maximum Conductor Size | 120 mm², 240 mm², 300 mm², 400 mm², 630 mm² |
Maximum Conductor Size (Imperial) | 250 kcmil, 500 kcmil, 600 kcmil, 750 kcmil, 1243 kcmil |
Maximum Installed Length | 8.50 in |
Minimum Conductor Size | 25 mm², 70 mm², 95 mm², 120 mm², 185 mm², 240 mm², 400 mm² |
Minimum Conductor Size (Imperial) | 4 AWG, 2/0 AWG, 3/0 AWG, 250 kcmil, 400 kcmil, 500 kcmil, 750 kcmil |
Number of Conductors | 1 , 3 |
Number of Skirts | 0 , 8 , 12 |
Product Series | 7600-3-W |
Product Type | Cold Shrink |
Shielding Type | Wire Shield, Non-shielded, Tape Shield, UniShield® |
Smallest Saleable Unit | Kit, Each |
Voltage | 5 kV, 8 kV, 36 kV, 6/10 kV, 12/20 kV, 18/30 kV |
Voltage Application | Medium Voltage |
Voltage Rating | 12/20 kV, 19/33 kV, 26/45 kV, 6,35/11 kV |
Voltage Row | 12/20 kV |
Safety Data Sheets
Document Number: MSDS_2654440_GB_EN
(PDF)
Thank you for your interest in 3M. In order to help us manage and respond to your query effectively, we politely ask you to provide some key information, including your contact details. The information you provide will be used to respond to your request through email or telephone by a 3M representative or one of our authorised business partners with whom we might share your personal information consistent with the 3M privacy policy
We have received your message and are now looking into your enquiry
One of our representatives will get in touch with you by phone or email